Sign In | Join Free | My adobecards.com |
|
Categories | Flowmeter |
---|---|
Brand Name: | Consensic |
Model Number: | CAFS5012 |
Certification: | PTC23041812701C-CN01 |
Place of Origin: | WUXI |
MOQ: | Please contact us for details |
Price: | Offline conversation or face-to-face discussion |
Payment Terms: | L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments |
Supply Ability: | 999 |
Delivery Time: | 3-7 work days |
Methods of Communication: | RS485Modbus |
interface: | NTP1/2” |
Calibration method: | Air, 20°C, 101.325kPa |
Functional items: | CAFS5012 Response time 65 (10, 20, 30, 50, 80, 100, 200, etc.) ms optional |
precision: | ±1.5%F.S |
Response time: | 65 (10, 20, 30, 50, 80, 100, 200, etc.)msOptional |
Overall material: | Stainless steel (aluminum alloy can be customized) |
Flow range: | 0-50/100/200/300/400slpmCustomizable |
Product Packaging:
Shipping:
The cable connecting the flowmeter and the user interface is
connected as follows:
Color User input and output interface definitions
Red Power Positive (+)
Black Power Negative(-)
Green 485B
Blue 485A
Yellow Vout analog voltage output
Note: In the pin definition, RS485 communication (RS485A and
RS485B);
Power supply positive (+): is the external power supply positive
input Vin (8~24VDC);
Vout is an analog voltage 1-5V output model;
Power Negative (-): is an external power supply negative (also a
common GND)
Functional items | CAFS5012 communication mode RS485 Modbus joggle NTP 1/2” | ||
performance parameter | unit | remarks | |
Flow range | 0-50/100/200/300/400 | slpm | customizable |
Power Supply Voltage | 8~24VDC,50mA | VDC | selectable |
accuracy | ±1.5 | % | FS |
response time | 65 (10,20,30,50,80,100,200, etc.) | ms | selectable |
maximum pressure | 0.8 | MPa | customizable |
communication mode | RS485 | Modbus | |
Measure the scale ratio | 50:1 |
1. High accuracy (1.5% F.S accuracy)
2. Linear output and no temperature compensation required
3. Maintain long-term stability with minimal zero drift
4. Fast response time
5. The flow rate range is wide from 0-60m/s, and the impact
resistance is 100g
6. Solid-state sensing core (no surface voids or fragile
membranes), resistant to clogging and pressure shock
7. Analog output (1 to 5 V) (digital I2C communication output
available)
8. It can be adapted to the measurement of relatively humid gases
9. Operating temperature: -20°C to 65°C, storage temperature: -40°C
to 85°C, humidity: 0 to 99%RH
10. The sensor is resistant to condensation
![]() |