Fumonisin Rapid Mycotoxin Testing Kits For Grain Feed 50 Tests/Kit
1. Brief
This product is used for testing Fumonisin residue in grain and
feed. The whole test need about 5 -10min, suitable for on-site
rapid qualitative detection. The sensitivity is200ng/ml(200ppb).
2. Components
Fumonisin rapid test card | 50 pieces/kit |
Sample buffer | 1 tube |
Plastic disposable gloves | 4 pieces |
15 ml centrifuge tube | 2 pieces |
Manual | 1 piece |
3. Materials required but not provided
Centrifuge, micropipette
4. Sample preparation of grain and feed
Take above 5g of representative samples of feed and grain (rice,
wheat, corn, peanuts) to crush (through a 20-mesh sieve), weigh
accurately 2g crushed sample into the 15ml centrifuge tube, add
accurately 4ml sample buffer into the 15ml centrifuge tube, shake
and mix evenly for 1min, be static for 10min or centrifuge at 4000
rpm for 5min, the up-layer clear liquid is the sample ready to
test.
5. Operation procedures
Return the test card, prepared sample or standard into room
temperature before testing, do not open the foil bag without
preparation.
1) Open the foil bag, take out test card, mark the sample or
standard on the test card.
2) Use dropper absorb 4-5 drops (about 120ul) of up-layer clear
liquid, vertically add into “S” well on test card and begin timing.
For different sample and standard , please use different dropper
and test card.
3) Read the result after 10 minutes, It is invalid beyond 30mins.
6. Test Result Interpretation
6.1 Negative (—): Both C line andT line appear, the color of T line
is darker than or same as C line, it means the Fumonisin
concentration is lower than 200ug/kg or no Fumonisin residue.
6.2 Positive (+): The color of T line is lighter than C line or T
line is invisible, it means the Fumonisin concentration is higher
than 200ug/kg. The lighter of T line compare with C line, the
higher concentration of Fumonisin in sample.
6.3 Invalid: C line is invisible, maybe it is the operation error
or test card is invalid. Read the manual, use new test card to test
again. If the problem keep happening, please stop using this lot
no. product and contact local supplier.


7. Precautions
1) Use test card for once during expiry date;
2) Do not use test card out of expiry date, deal with the waste
properly;
3) Do not touch the white membrane surface in the middle of test
card;
4) Do not repeat use the dropper to avoid cross pollution; .
5) Do not eat any of the reagents;
6) If need to test standard directly, we can provide standard
buffer;
7) Contact the supplier for any questions.
8. Storage and expiry date
Storage: Store at 2-30 ℃ in dark,no frozen.
Expiry date: 18 months; date of production is on box.

Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.
Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific
needs and specific quantities.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so
far all the production process, we have standard rules, we comply
with the relevant behavior and laws of the government.
Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service.
If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.
Q5: What is your minimum order quantity?
A5: 1Kit.
Q6: What is the shipping method?
A6: It can be shipped by express (FEDEX, UPS, DHL, EMS, etc.) or by
air and ground.Please confirm with us before placing an order.