Sign In | Join Free | My adobecards.com |
|
Categories | Power Plant Accessories |
---|---|
Brand Name: | Ze Xu |
Model Number: | 3/4”-10” |
Certification: | API |
Place of Origin: | Yanshan County, Cangzhou City, Hebei Province, China |
MOQ: | 1 item |
Price: | 100 USD per piece |
Payment Terms: | T/T |
Supply Ability: | 10,000 pieces per month |
Delivery Time: | 10 working days |
Packaging Details: | Wooden box pallet or according to customer needs |
Material: | 304 |
shape: | Round shape |
Product surface: | Solid solution or pickling |
Section shape: | Round tube |
Product Features: | long life |
Tube end shape: | Flat |
304 Stainless Steel Boiler Coils, Special-Shaped Coils, Coils Can Be Processed According To The Drawing
Generally speaking, stainless steel coils have different
classifications according to their different fields of use. We can
divide them into industrial use, mechanical structure use and fluid
use. Among them, industrial coils are used in heat exchangers,
boilers, petroleum, chemical and other fields; and stainless steel
coils for fluids are mostly used in beverages, beer, milk, water
supply systems and other fields; as for mechanical structures,
coils are used. In fact, it is used more in the fields of printing
and dyeing, printing, textile machinery, medical equipment, kitchen
equipment and so on. The effects and functions of different types
of coils are different.
Coil application range: boiler pressure vessel, petroleum,
chemical, shipbuilding, pharmaceutical, metallurgy, machinery,
stamping elbow food and other industries.
Product Name: Stainless Steel Coil | Brand: Zexu |
Caliber: 3/4 inch-10 inch | Material: carbon steel, alloy steel, stainless steel, duplex steel, etc. |
Pressure: 0.1-25 kg |
Stainless steel coil processing manufacturer's experience in
repairing and processing stainless steel coils and capillary tubes
1. The inlet of the capillary tube should be connected to the top
of the evaporator coil. 2. After the freezer coil is not well
controlled, the return air pipe outside the box will be frosted if
the amount of refrigerant injection is not well controlled. You can
put some refrigerant when the return air pipe condenses. 3. It is
normal that the upper part of the coil does not form frost and the
lower part does not form frost. During the test machine, there is
no food to be frozen in the box, and the humid air content in the
box is low, so only the upper part is frosted. It is normal for the
lower part to feel smooth by hand. You can touch the lower tube
with a towel wet with water. If the wet towel can stick to the
tube, it proves that the refrigerant is just enough. If it does not
stick or the hand feels no smoothness, then only check other Up.
4. The pitch of the coils is generally 5CM, and they are arranged
naturally in layers from top to bottom. Choose 8-10MM copper tube.
Note: Incorrect copper pipe arrangement will cause oil accumulation
in the pipeline, which will cause sequelae such as poor circulation
of the refrigeration system over time. 5. The inner diameter of the
capillary tube is selected from 0.4mm to 1.78mm. Under normal
circumstances, the refrigerator is selected between 0. 4-0. 6mm.
The freezer is selected between 0. 6-0. 8mm. The refrigerated
cabinet is selected between 0.8-1mm.
6. The length of the capillary tube: The freezer is at 2.8-4. 0m.
The length of the capillary tube is not. It is determined according
to the ratio of the high and low pressure ends after the
refrigeration system is stable. The ratio of the high and low
pressure ends is: 1. 5Mpa/0.06Mpa,.
7. The copper tube uses 8MM, and the length is determined according
to the actual volume. The simple way is to use small-capacity
refrigerators and freezers. The distance between the tubes is
4-6CM. For more than 300 liters, the separation distance is 8-10CM.
The cooling can be made uniform, and the length can be calculated
in advance. After the pipe is folded in half, the double pipes are
coiled at the same time, so that the inlet and the outlet can be
handled at the same position. As for the refrigerating room, just
buy a finished blown-up type.
8. The cut-off flow rate of the capillary tube is directly related
to the displacement of the compressor, and it also determines the
working pressure of the condenser. So choose well. The empirical
formula is: compressor power W*2=capillary length. After getting on
the machine, fine-tune it according to the actual situation.
Example 125w*2=capillary length 250.
9. Regardless of the length of the capillary tube outside the
original box, keep the original length, and connect the capillary
tube of the same specification with a length of 1. 2-1. 5m
originally buried in the box body.
Hebei Zexu Pipe Manufacturing Co., Ltd. is an enterprise that
produces and customizes various specifications of mosquito coils,
semi-circular tubes, angle steel, coils, U-shaped tubes, and head
coils. Welcome to consult! !
![]() |