Sign In | Join Free | My adobecards.com
adobecards.com
Products
Search by Category
Home >

Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit

Categories Air Cooled Modular Chiller
Brand Name: Euroklimat
Model Number: EKAC460BR1
Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Place of Origin: China
MOQ: 1pcs
Price: negotiation
Payment Terms: T/T or western Union
Supply Ability: 3,000pcs per month
Delivery Time: 10 working days after received your payment
Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
COP: 3.35
Refrigerant: R410A
Heating Capacity: 142-2272kW
Cooling Capacity: 134-2144 kW
Number Of Modules For A Modular Unit:: 16 pcs Units
Test Center: The EK Test Center Has Been Approved By The China National Accreditation Service For Conformity Assessment (CNAS).
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit


    Environmentally-Friendly Refrigerant-Type Modular Air-Cooled Heat Pump Unit


    Specifications:


    Technical data sheet


    Model EKAC 460B1EKAC 460BR1EKAC 920B1EKAC 920BR1EKAC 1380B1EKAC 1380BR1
    Combination methodMasterEKAC 460B1MEKAC 460BR1MEKAC 460B1MEKAC 460BR1MEKAC 460B1MEKAC 460BR1M
    Slave----EKAC 460B1SEKAC 460BR1S2EKAC 460B1S2EKAC 460BR1S
    Nominal refrigerating capacitykW138138276276414414
    USRT39.2439.2478.4878.48117.72117.72
    x104
    kcal/h
    11.8711.8723.7423.7435.6135.61
    x104
    Btu/h
    47.1047.1094.294.2141.3141.3
    Nominal heating capacitykW--148--296--444
    USRT--42.08--84.16--126.24
    x10
    4kcal/h
    --12.73--25.46--38.19
    x104
    Btu/h
    --50.51--101.02--151.53
    Total power consumption under nominal refrigerating capacitykW40.840.881.681.6122.4122.4
    Total power consumption under nominal heating capacitykW--42.5--85.0--127.5
    Power supply 380 V/3N~/50 Hz
    RefrigerantType R410A
    Control Electronic expansion valve
    CompressorType Full hermetic scroll compressor
    Lubricant Lipid oil (POE-160SZ)
    Qty.Piece224466
    FanType Axial large-blade low-noise fan
    Qty.Piece224466
    Water-side heat exchangerType High-efficiency vacuum brazed heat exchanger
    Refrigerating water flow ratem3/h23.723.747.447.471.171.1
    Heating water flow ratem3/h25.5h25.550.950.976.476.4
    Water resistancekPa424242424242
    Recommended length of inlet/outlet water pipeinch≥3≥3≥4≥4≥5≥5
    Power wireCross- sectional area of main wiresmm235359595185185
    Qty. of main wires 3
    Cross- sectional area of neutral wiremm2610
    Qty. of neutral wires 1
    Cross- sectional area of ground wiremm2161650509595
    Qty. of ground wires 1
    DimensionsL x Hmm2200×2260
    Wmm115011502900290046504650
    Weight of unitNet weightkg99010201980204029703060
    Weight of unit during runningkg100510352010207030153105

    Model EKAC1840B1EKAC1840BR1EKAC2300B1EKAC2300BR1
    Combination methodMasterEKAC460B1MEKAC460BR1MEKAC460B1MEKAC460BR1M
    Slave3EKAC460B1S3EKAC460BR1S4EKAC460B1S4EKAC460BR1S
    Nominal refrigerating capacitykW552552690690
    USRT156.96156.96196.2196.2
    x104
    kcal/h
    47.4847.4859.3559.35
    x104
    Btu/h
    188.4188.4235.5235.5
    Nominal heating capacitykW--592--740
    USRT--168.32--210.4
    x10
    4kcal/h
    --50.92--63.65
    x104
    Btu/h
    --202.04--252.55
    Total power consumption under nominal refrigerating capacitykW163.2163.2204204
    Total power consumption under nominal heating capacitykW--170.0--212.5
    Power supply  
    RefrigerantType  
    Control  
    CompressorType  
    Lubricant  
    Qty.Piece881010
    FanType  
    Qty.Piece881010
    Water-side heat exchangerType  
    Refrigerating water flow ratem3/h94.894.8118.5118.5
    Heating water flow ratem3/h101.8101.8127.3127.3
    Water resistancekPa42424242
    Recommended length of inlet/outlet water pipeinch≥6≥6≥6≥6
    Power wireCross- sectional area of main wiresmm2240240185185
    Qty. of main wires  6
    Cross- sectional area of neutral wiremm2 
    Qty. of neutral wires  
    Cross- sectional area of ground wiremm2120120185185
    Qty. of ground wires  
    DimensionsL x Hmm 
    Wmm6400640085108510
    Weight of unitNet weightkg3960408049505100
    Weight of unit during runningkg4020414050255175

    Notes:
    ■ Working conditions of the unit for testing the nominal refrigerating capacity: Outlet temperature: 7°C; water flow rate: 0.172 m3/(h•kW); outdoor temperature: 35°C
    ■ Working conditions of the unit for testing the nominal heating capacity: Outlet temperature: 45°C; water flow rate: 0.172 m3/(h•kW); outdoor psychrometric difference: 7°C or 6°C
    ■ Water resistance includes differential water pressure of the unit and that of the affiliated Y-shape filter.
    ■ For combined units, the manufacturer does not offer general water pipes and they must be prepared and installed on site. Diameter of the pipes should comply with design standards.
    ■ A modular unit can be combined by same or different modules based on actual requirements; up to 16 modules can be built into a modular unit. The parameters listed in the table above are
    for commonly combined units.
    ■ Power distribution and wiring are subject to unit nameplates or installation guide.


    Description:


    1, The innovative EK air conditioner adopts the leading air-cooled heat pump design in Europe which enables an energy efficiency ratio (EER) in full load mode exceeding Chinese energy-saving product certification standard (higher than COP3.2).

    2, EKAC460BR1 series air-cooled modular unit adopts R410A. Compared with the conventional refrigerant R22, R410A does not contain chlorine and therefore has no adverse impact on the ozonosphere. It serves as a medium- and long-term substitute of R22.

    3, RoHS-certified environmentally-friendly zinc-plated steel boards are adopted to ensure an endurable body which is resistant against corrosion, peeling, and fading.

    4, The ring-shape return air heat exchanger enables more evenly air flow and higher efficiency.

    5, The electric control cabinet is covered with sheet metals both internally and externally. All internal elements are internationally renowned brand products..

    6, The 500-level PMV electronic expansion valve ensures precise flow control. Degree of superheat can be precisely matched when the unit’s load changes.

    7, A dual-speed condenser fan with blades passing the dynamic and static balance test is driven by a high-efficiency motor to realize efficiency and quietness at night..

    8, The compressor uses internationally leading technologies, including axial end sealing technology, radial oil membrane sealing technology, and new electronic protection technology. The large oil pool and the gigantic space at the absorption side, together with the liquid-gas separation function, ensure large charging capacity.

    9, The dual-system plate heat exchanger can bear up to 3.0 MPa pressure at the water side, applicable to water systems of super-high buildings.

    10, The LOVATA inner grooved copper tube ensures reliable quality and high heat exchange rate.

    11, The unit adopts anti-vibration design and multi-level noise reduction. The brand quiet full-hermetic scroll compressor; dual-speed quiet motor; blades passing the dynamic and static balance test ensures industry leading noise reduction grade and anti-vibration degree.

    12, Lower-part hermetic structure: The lower part of the unit is covered with sheet metals to insulate noise of a running compressor.

    13, An innovative smart silence mode is adopted. The fan speed (high/low gear) can be automatically adjusted based on unit’s running state and ambient temperature to allow a unit to work in quiet and low-noise mode. The noise at night is reduced by 6 dB (A).

    14, The EK test center has been approved by the China National Accreditation Service for Conformity Assessment (CNAS). By national-level test (with respect to corrosion, fatigue, frequent startup, etc), the modular unit is highly reliable.

    15, Defrosting conditions are automatically to save energy. Defrosting capability varies depending on the amount of frost, to maximize normal heating time and minimize temperature change caused by defrosting.

    16, The EK system can be composed of up to 16 modules. Any slave module of the system can take over works of a faulty master module, posing no adverse impact on the entire system. Besides, a part of load of the EK system is born alternately to balance load of the compressor.

    17, A modular unit is equivalent to two conventional modular units, saving up to 40% installation space.

    18, The unit helps you save investment into water system. A modular unit is equivalent to two conventional modular units, helping you save investment into an additional set of pipelines and accessories.

    19, The unit provides 13 powerful in-built protection functions, including: High-low pressure protection, inverse phase or lack-of-phase protection, frequent start protection, overcurrent protection, discharge temperature protection, overheat protection, sensor fault protection, chiller antifreeze protection, water system antifreeze protection, low water flow protection, and ambient temperature protection.

    20, The unit adopts a microcomputer control system and a large LCD to facilitate operation. A single control system can control up to 16 units and monitor their running state in real time. The optional RS485 COM interface is embedded with the Modbus protocol to realize group control.


    Applications:


    These units are applicable to places such as hotels, restaurants, recreational centers, hospitals, dining halls, offices, cinemas, factories, and supermarkets, especially to those rising high requirement on noise reduction and ambient environment and where water is lacking or cooling water tanks are inapplicable.


    Competitive Advantage:


    EKAC series environmentally-friendly refrigerant-type air-cooled heat pump units combine the essence of Euroklimat accumulated over 40-year air-cooled heat pump design experience with the demand in the modular unit market of China, to fully satisfy customers requirements on efficiency, environmental friendliness, comfort, safety, and smartness to the greatest extent. These units are applicable to places such as hotels, restaurants, recreational centers, hospitals, dining halls, offices, cinemas, factories, and supermarkets, especially to those rising high requirement on noise reduction and ambient environment and where water is lacking or cooling water tanks are inapplicable.

    Featuring flexibility in installation, quickness in construction, and simplicity in pipelining, these units allow phase-based and moderate investment and have no requirement on the chilled water system, therefore becoming one of the best choices for users.

    Quality Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit for sale
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0