Sign In | Join Free | My adobecards.com
adobecards.com
Products
Search by Category
Home > Electronic Measuring Instruments >

KINGSINE KT210 Current Transformer Analyzer CT/PT Parameters Test

Categories CT Analyzer
Brand Name: KINGSINE
Model Number: KT210
Certification: CE/ISO9001
Place of Origin: China
MOQ: 1 set
Price: Negotiation
Payment Terms: L/C,T/T
Supply Ability: 100 sets/month
Delivery Time: 15 working days
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    KINGSINE KT210 Current Transformer Analyzer CT/PT Parameters Test

    Easy to operate CT / PT Analyzer,
    120V / 15A Current Output,
    9.7 inch touch screen operation,
    IEC60044-1, IEC60044-6, IEC61869-2, ANSI30/45 standard
    High stability for bushing CT testing;


    Adopt 9.7 inch touch screen TFT LCD display with clear and beautiful software interface design, user can operate easily.
    AC/DC current input for wide range only, satisfy all power supply standard requested.
    Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.
    Adopt low voltage & variable frequency measurement method, it can test knee point voltage up to 30kV transformer as output max voltage only is 120V and max peak value current is 15A, high security.
    Portable design with light weight of 8kg, suitable for field test of electric power system, manufacturing factory of current transformer or laboratory to use.
    High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000).
    It can test current transformer according to IEC60044-1, IEC60044-6, IEC61869-2 and ANSI30/45 standard etc.
    Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.
    PT Test As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT210 CT/PT Analyzer can also test them. KT210 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT.


    Auto Demagnetizes
    Software-based tool to determine the residual magnetism in current transformers
    Analysis of the remanence condition before putting into operation the CT to assure proper function
    Simplifies power grid failure analysis after unwanted operation of protective relays
    Demagnetizes the CT core after measurement
    PC Control Available
    Full access to all functions of the KT210 via a PC using the RJ45 interface
    Optimizes the integration into automated testing procedures in production lines
    Data export into Word
    Customizable testing and reports
    Data Handling and Reporting
    Test reports can be saved on the local host and transferred to a PC
    Data and protocols can be shown on a PC via the Word file loader program
    "Guessing" Nameplates(Reference for unknown CT)
    Determination of unknown CT data
    Older CTs can be classified and put into service without contacting the manufacturer
    Determinable parameters include:
    CT type
    Class
    Ratio
    Knee point
    Power Factor
    Nominal and operating burden
    Secondary winding resistance

    Technical Features
    Excellent noise immunity to disturbances from energized power lines close to the measurement
    CT ratio and phase measurement with consideration of nominal and connected secondary burden; CT ratio up to 10000:1
    Knee-point voltage from 1 V up to 30 kV can be Measured
    Currents from 1% up to 400 % of the rated value
    Different burdens (full, ½, ¼, ⅛ burden)
    Determination of ALF/ALFi and FS/FSi, Ts, and composite error for nominal and connected burden
    CT winding resistance measurement
    CT excitation curve (unsaturated and saturated)
    Saturation characteristic recording
    Direct comparison of excitation curve to a reference curve
    CT phase and polarity check
    Secondary burden measurement
    Automatic demagnetization of the CT after the test
    Small and lightweight (< 8 kg)
    Short testing time due to fully automatic testing
    High level of safety using patented variable frequency method (max. 120 V)
    "Nameplate guesser" function for CTs with unknown data
    PC control interface
    QuickTest: Manual testing interface
    Color display readable in bright sunlight
    Simulation of measured data with different burdens and currents
    Easily adaptable reports (customizable)
    Knee-point voltage from 1 V up to 30 kV can be Measured
    Automatic assessment according to IEC 60044-1, IEC 60044-6, IEC61869-2, ANSI30/45
    Automatic assessment for accuracy class > 0.1
    Measurement of transient behavior of TPS, TPX, TPY and TPZ type CTs

    PT ratio, polarity and excitation curve according to IEC60044-2


    Technical Data of KT210 CT/PT Analyzer
    Ratio Accuracy
    Ratio 1 - 50000.03 % (typical) / 0.1 % (guaranteed)
    Ratio 5000 - 100000.05 % (typical) / 0.2 % (guaranteed)
    Phase Displacement
    Resolution0.01 min
    Accuracy1 min (typical) / 3 min (guaranteed)
    Winding Resistance
    Range0.1 - 100 Ω
    Resolution1 mΩ
    Accuracy0.05 % + 1 mΩ (typical) (guaranteed)
    0.1 % + 1 mΩ (guaranteed)
    Load Measurement
    Range0~300VA
    Resolution0.01VA
    Voltage Measurement Input
    Secondary Input Range0~300V
    Max Knee point30KV
    Secondary Input Accuracy±0.1%
    Primary Input Range0~30V
    Primary Input Accuracy±0.1%
    Output
    Output Voltage0 Vac to 120 Vac
    Output Current0 A to 5 A (15 A peak)
    Output Power0 VA to 450 VA (1500 VA peak)
    Main Power Supply
    Input Voltage176 Vac to 264 Vac @ 10A Max
    Permissible Input Voltage120 Vdc to 370 Vdc @ 5A Max
    Frequency50 / 60 Hz
    Permissible Frequency47 Hz to 63 Hz
    ConnectionStandard AC socket 60320
    Physical Dimensions
    Size (W x H x D)360 x 140 x 325mm
    Weight<8 kg (without accessories)
    Environment Conditions
    Operating Temperature-10°C up to + 55°C
    Storage Temperature-25°C up to + 70°C
    HumidityRelative humidity 5% up to 95% not condensing

    Quality KINGSINE KT210 Current Transformer Analyzer CT/PT Parameters Test for sale
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0